CALL SUPPORT

+92 333 0862202

EMAIL SUPPORT

sales@arsontrade.com

LOCATION

Gulshan -e-Iqbal Karachi, Pakistan

Active Harmonic Filters

Active Harmonic Filter — Arson Engineering

Active Harmonic Filters

Arson Engineering supplies and commissions Active Harmonic Filters (AHF) that detect and cancel harmonic distortion in real time — keeping your electrical network clean, compliant, and efficient.

Built on Schneider Electric technology and backed by ETAP-based power system analysis, our AHF solutions are sized specifically for your load profile, not sold off a generic spec sheet.

<5%
Achievable THD
Real-Time
Harmonic Correction
IEEE 519
Compliance Ready
Active Harmonic Filter panel placeholder

Harmonics are costing you more than you think

Non-linear loads — VFDs, UPS systems, LED drivers, rectifiers — inject harmonic currents that distort your network.

Harmonic distortion diagram placeholder

Without correction

  • Overheating transformers, cables, and neutral conductors
  • Nuisance tripping of breakers and protection relays
  • Reduced power factor and higher utility penalties
  • Premature failure of sensitive electronic equipment
  • Non-compliance with IEEE 519 / grid-code limits

With Arson's AHF

  • Real-time, load-responsive harmonic cancellation
  • THD reduced to well within regulatory limits
  • Improved power factor and lower energy losses
  • Extended equipment lifespan across the network
  • Full compliance documentation from ETAP-based studies

Engineered for your actual load

Every installation starts with a power quality study — not a catalogue selection.

01

Site-Specific Sizing

AHF capacity is calculated from your actual harmonic spectrum via ETAP power quality analysis, not a rule of thumb.

02

Real-Time Response

Continuously monitors load current and injects compensating current within milliseconds to cancel distortion.

03

Modular & Scalable

Add filter modules as your load grows, without redesigning the entire power quality system.

04

Schneider Electric Backed

Sourced and commissioned as an authorized Schneider reseller, with full manufacturer warranty support.

05

Remote Monitoring

Optional SCADA / ETAP integration for live THD and power factor visibility across your facility.

06

Turnkey Commissioning

Supply, installation, testing, and commissioning handled end-to-end by our in-house engineering team.

Built for harmonic-heavy environments

Textile & Manufacturing Plants Data Centers Hospitals Commercial Towers Oil & Gas Facilities Substations & Utilities Solar & Renewable Sites Water Treatment Plants
Technical drawing placeholder

Indicative specifications

Final specification is confirmed after site load analysis. Values below are typical ranges.

Rated Current Range30A – 300A per module (scalable)
Harmonic Orders Compensated2nd – 51st
THD ReductionDown to < 5%
Response Time< 20 ms
Power Factor CorrectionUp to 0.99
ConnectionParallel, non-intrusive to existing network
MonitoringLocal HMI, optional SCADA/ETAP integration

Get your site's harmonic profile assessed — free.

Our engineers will review your load type, run a power quality analysis, and recommend the right AHF configuration for your facility.

Powered by Joinchat